Stryker hand plattensystem pdf kostenfreier download. Stryker hand plating system hydroset injectable ha. Please contact your stryker representative if you have questions about the availability of stryker products in your area. The role of locking technology in the hand hand surgery, pc. Read it thoroughly before beginning any maintenance on the equipment. V olar locking plate fixation is an increasingly popular method for surgical treatment of a fracture of the distal radius. Find your stryker ifu distributed intellivue mx40 patient cable adapter, trunk, and extender cables distributed intellivue mx40 singleusepatient cables distributed oem trunk cable adapters distributed philips intellivue trunk cables. The variaxhandlockingplatemodule is a plating system which offers the bene. The angled reamer driver is offset 45 degrees from center and is designed to facilitate the contouring of the glenoid face in those cases. Biomechanical performance of variable and fixed angle locked.
Specifications maximum weight capacity 500 pounds overall bed lengthwidth 83. Variax hand locking plate module operative technique variax locking plates select an appropriate sized implant. The variax hand locking and profyle hand system which offers the benefits of a comprehensive range of variable angled locking and nonlocking plating options to treat a full range of hand fractures. Universal 2 reference guide a surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Comprehensive plating system providing anatomical volar and dorsal, universal volar and fragment. Osteosynthesis variax distal radius locking plate system. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. When it comes to hand and wrist treatment we have you covered. Specifications 1210 1710 overall bed length \ width 84 31. Intercrossing locking screws securely hold the ulnar head. This operative technique was developed with richard rogachefsky, md. Variable angle locking hand system implants are intended for temporary. The variax hand system consists of 33 locking plates which offer several options to the surgeon for more flexibility.
This manual is designed to assist you with the operation of the model 1210 emergency care stretcher, and the model 1710 pacu stretcher. Comprehensive plating system providing anatomical volar and dorsal, universal volar and fragment specific solutions, even for the most complex distal radius fracture. Therefore, the biomechanical testing was designed to closely replicate the in vivo forces at the fracture site shortly following fixation and described in detail below. Comprehensive plating system providing anatomical volar and dorsal, universal volar and fragment speci. Stryker corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks. Screening under image intensification demonstrated a stable reduction with no ulnar subluxation or dislocation and. Recent clinical trials have demonstrated more rapid return of function with volar locking plates compared with. The restoration ha hip system is designed to address the problems of revision surgery where extensive fixation, both distally and proximally, is required for support of the prosthesis. Strykers orthopaedics division releases three new plating. New t7 drive screw head design axial stability friction fit easy screw pick up patented smartlock. View online or download stryker s3 medsurg bed operation manual, quick start manual. Variax distal radius locking plate system osteosyntese. Type ii anodization the locking plates are processed with a type ii anodization treatment which improves the biomechanical performance and may reduce the incidence of tissue adherence. Variable angle locking plate system for reconstruction or arthrodesis of small bones, including the fore, mid and hind foot and ankle.
The variax module offers polyaxial locking platescrews in 2. The stryker variax clavicle system has not been evaluated for safety and use in the mr environment and has not been tested for heating or migration in the mr environment, unless speci. The stryker hand plating system was the profyle hand standard plating indications developed with one thing in mind, to module builds upon the strong be recognized as one of the most foundation of the profyle, which has intended for use in internal. Description part number parts list electricelectronic components motor control board qdf230315 ol280116117 scale. Replantation joint fusions corrective osteotomies osteopenic bone.
Variax distal radius locking plate system stryker meded. Stryker the stryker variax hand locking module strykerleibinger,kalamazoo,mi,usabuildsonthiscompanys profyle hand standard plating module,44 a nonlocking platescrew system with 2. Core tray includes one set of t8t10 screws plus standardized instrumentation and reduction instruments across various small fragment indications. The stryker hand plating system was developed with one thing in mind, to be recognized as one of the most comprehensive mini fragment fixation systems. The variax 2 system is an internal fixation device consisting of screws and instrumentation that will be used in conjunction with previously cleared variax plating systems to treat a number of different types of fractures in the radius, ulna. Stryker craniomaxillofacial kalamazoo, mi 49002 usa t. Operative technique manuals please click on the link below for the technique manual of interest. Our comprehensive portfolio will fit your need to treat fractures, small joint arthroplasty, fusions and soft tissue procedures. Variable angle locking plate system for treatment of small bones including the hand and wrist. Maintenance chapter 2 recommended spare parts the following is a list of recommended on hand spare parts for the fl28c bed. The stryker hand plating system was developed with one thing in mind, to be recognized as one of the most comprehensive mini fragment. The stem is fabricated of titanium alloy which has been roughened by a chemi cal etching process. The new variax distal radius plating system represents the next generation of bone fixation for your distal radius fracture needs.
Biomechanical performance of variable and fixed angle. The variax clavicle locking plate system is an anatomically shaped, variable angled locking plate system. The variax hand locking plate module offers variable angled locking plates as well as nonlocking plates and screws for 1. Indications the variable angle locking hand system is indicated for the treatment of fractures, deformities and degenerative diseases in the hand. Locked volar fixation is designed to permit early hand and wrist range of motion. Osteosynthesis variaxtm distal radius locking plate system. The stryker variax 2 system is intended for use in internal fixation, reconstruction and treatment of fractures in the foot and ankle in adult and adolescent 1221 years patients. The variax distal radius plating system represents the next generation of bone fixation for your distal radius fracture needs. The first three ranks went to the stryker variaxplates. It offers guidance that you should heed, but, as with any such technical. Increases the strength of all variax distal radius locking plates and reduces the incidence of tissue adherence. Variax 2 onethird tubular plating system indications for use describe the stryker variax 2 onethird tubular plating system is intended for internal fixation of fractures of the clavicle, scapula, olecranon, humerus, radius, ulna, pelvis, distal tibia, fibula, small bones in the ankle, fore, mid.
This fracturegap model was fixated using one of three different locked volar distal radius plates. Postoperatively, the wrist was bandaged for 2 weeks, and active finger flexion and extension exercises and shoulder and elbow exercises were encouraged. Read it thoroughly before using the equipment or beginning any maintenance on it. The variax hand locking plate module is a plating system which offers the bene. Variax 2 foot stryker foot plating system operative technique. Stryker 620362 system 6 dual trigger wire collet for use with the stryker 6205 dual trigger rotary handpiece for wire sizes 0. Leibinger handchirurgie stryker hand plattensystem operationstechnik variax modul mit winkelstabilen platten profyle modul mit standardplatten stryker hand. Hydroxylapatiteis then plasmasprayed over the entire length. Contact careers about privacy policy terms of use site map. Related stryker products the stryker hand plating system is a truly comprehensive system which offers you the locking and nonlocking options necessary to treat a full range of hand and wrist fractures which present daily. Strykers new variax locked plating systems feature more options than other systems, allowing surgeons to provide a more customized solution. Operative technique manuals grabow hand to shoulder center. A servohydraulic testing machine mts bionix, eden prairie, mn delivered axial compression, and dorsal and volar threepoint bending at sub.
Stryker hand plating system operative technique 4 modular tray design the stryker hand plating solution consists of two modules with interchangeable inlays. You can angle locking screws up to 10 in each direction for a total range of 20. The stryker hand plating system was developed with one thing in mind, to be recognized as one of the most comprehensive min ifragment. Variax 2 foot is indicated for internal fixation of bones in the foot, ankle, hand, and wrist in adult and adolescent 1221.
Step 2 place the appropriate locking drill guide in the hole of the plate and aim. Variax hand locking plate module profyle hand standard plating module stryker hand plating system. Plates utilize smartlock technology which permits polyaxial screw placement. At 2 weeks, dressings were removed and physiotherapy commenced, with an aim to achieve. Introduction 1 pointed hooks and locking screw in the head pointed hooks to grip the styloid process and to act as reference point for plate application. Variable angle locking plate system for treating volar and dorsal distal fractures. In addition to the straight reamer driver, the reunion tsa shoulder system also includes an optional angled reamer driver. This publication sets forth detailed recommended procedures for using.
The variax 2 small fragment platform is designed to offer a comprehensive, modular and easytouse platform for treating various small fragment indications including clavicle, humerus, radius, ulna, fibula, foremid and hind foot. Stryker variax hand keyword found websites listing. Volar locking plate osteosynthesis for distal radial fractures. Yamaha stryker service repair manual yamaha stryker pdf.
869 75 521 234 1549 230 1087 38 764 877 265 1306 1351 519 1082 1077 462 239 143 598 1560 23 456 448 34 1375 106 1309 470 670 447 773